Direkt zum Inhalt Direkt zum Hauptmenü Direkt zur Fußzeile
Cover Texte 52/2015 Validation and quality assurance of methods for the substance flow analysis for large carbon dioxide loads from CO2 separation in CCS power stations
Klima | Energie

Validation and quality assurance of methods for the substance flow analysis for large carbon dioxide loads from CO2 separation in CCS power stations


This report describes the specification of a suitable measurement system for the qualitative and quantitative assessment of fluids with a high carbon dioxide content, as is typical for CCS systems. The use of continuous CO2 measurement equipment in industrial plant is possible. The measurement method used works reliably with the established quality assurance measures. Compliance with the highest tier in accordance with the Monitoring and Reporting Regulations is not possible. The uncertainty must be determined individually for the respective measurement equipment and optimised, if applicable. There are no test results for flow meters which can be used with compressed waste gas. By comparison with the measurement methods used for atmospheric measurements, a large error contribution is to be expected due to this. Further investigations and development by equipment manufacturers are required.


Reihe Texte | 52/2015 Seitenzahl 55 Erscheinungsjahr Autor(en) Bernhard Hoff, Hans Schmidt Sprache Englisch Forschungskennzahl 3710 41 504 Verlag Umweltbundesamt Zusatzinfo PDF ist barrierefrei Dateigröße 2,24 MB Druckversion nicht verfügbar

Schlagworte

Kurzlink: www.umweltbundesamt.de/n34163de